Geometric modeling and processing

Ambito disciplinare

  1. Articolo su rivista2019

    Measurement of high flexibility components in composite material: critical issues and possible solutions

    Polini W., Corrado A., Sorrentino L., Speranza D.,

    International Journal of Advanced Manufacturing Technology, 103(1-4), pp. 1529-1542

    3D scanningGeometric dimensioning, tolerancing and inspection

    Abstract

    High-flexibility components in composite material are of great interest in many fields, from aeronautic and automotive industries to sport and design goods. Their deformation during cure process, known as spring-in and warpage, is acceptable if it is within the indicated tolerance. The research aim of the present work is to present a way to inspect a high flexible part in composite material by means of a coordinate measuring machine with a touch probe. This means to define the fixturing equipment and the measurement strategy. The developed method was applied to an L-shaped part with a very small thickness and the obtained measurements were compared with those due to a laser system. The results show a good agreement between the two measurement techniques. Moreover, the further numerical simulations validate the developed contact measurement method.

    Keywords: Composite material , Coordinate measuring machine , Flexible component , Laser

  2. Articolo su rivista2019

    Preliminary CAD implementation of EU-DEMO primary heat transfer systems for HCPB breeding blanket option

    Tarallo A., Moscato I., Bubelis E., Barucca L.,

    Fusion Engineering and Design, 146, pp. 2062-2065

    Abstract

    This paper focuses on the 3D CAD implementation of the pipework and the main equipment of the Primary Heat Transfer System of EU-DEMO fusion power plant. In particular, the systems related to the Helium-Cooled Pebble Bed Breeding Blanket option are considered here. During the pulse operation, the breeding blanket modules will be the main thermal power source; Divertor and the Vacuum Vessel will contribute in the definition of the total reactor power. All the In-Vessel generated power is rejected to the Power Conversion System through a molten salt Intermediate Heat Transport System. The latter is equipped with an Energy Storage System to allow for continuous operation also during the dwell time. The layout of the pipework considered the major design constraints, such as the reinforced concrete structures and the dimensions of the main pieces of equipment. The size of the pipes was selected based on operating pressure, temperature and allowable velocity. Results provide a first estimation of length and weight of the piping systems as well as their space occupancy. These data are useful to evaluate the coolant inventory, as well as the expected pressure drops and plant cost.

    Keywords: EU-DEMO , Helium-Cooled Pebble Bed Breeding Blanket , ITER , Piping design , Primary heat transfer system

  3. Articolo su rivista2019

    Surgical treatments for canine anterior cruciate ligament rupture: Assessing functional recovery through multibody comparative analysis

    Putame G., Terzini M., Bignardi C., Beale B., Hulse D., Zanetti E., Audenino A.,

    Frontiers in Bioengineering and Biotechnology, 7(AUG)

    Product design and engineering

    Abstract

    Anterior cruciate ligament (ACL) deficiency can result in serious degenerative stifle injuries. Although tibial plateau leveling osteotomy (TPLO) is a common method for the surgical treatment of ACL deficiency, alternative osteotomies, such as a leveling osteotomy based on the center of rotation of angulation (CBLO) are described in the literature. However, whether a CBLO could represent a viable alternative to a TPLO remains to be established. The aim of this study is to compare TPLO and CBLO effectiveness in treating ACL rupture. First, a computational multibody model of a physiological stifle was created using three-dimensional surfaces of a medium-sized canine femur, tibia, fibula and patella. Articular contacts were modeled by means of a formulation describing the contact force as function of the interpenetration between surfaces. Moreover, ligaments were represented by vector forces connecting origin and insertion points. The lengths of the ligaments at rest were optimized simulating the drawer test. The ACL-deficient model was obtained by deactivating the ACL related forces in the optimized physiological one. Then, TPLO and CBLO treatments were virtually performed on the pathological stifle. Finally, the drawer test and a weight-bearing squat movement were performed to compare the treatments effectiveness in terms of tibial anteroposterior translation, patellar ligament force, intra-articular compressive force and quadriceps force. Results from drawer test simulations showed that ACL-deficiency causes an increase of the anterior tibial translation by up to 5.2 mm, while no remarkable differences between CBLO and TPLO were recorded. Overall, squat simulations have demonstrated that both treatments lead to an increase of all considered forces compared to the physiological model. Specifically, CBLO and TPLO produce an increase in compressive forces of 54% and 37%, respectively, at 90â—¦ flexion. However, TPLO produces higher compressive forces (up to 16%) with respect to CBLO for wider flexion angles ranging from 135â—¦ to 117â—¦ . Conversely, TPLO generates lower forces in patellar ligament and quadriceps muscle, compared to CBLO. In light of the higher intra-articular compressive force over the physiological walking range of flexion, which was observed to result from TPLO in the current study, the use of this technique should be carefully considered.

    Keywords: CBLO , Ligaments , Multibody , Simulation , TPLO

  4. Contributo a convegno2019

    DOCUMENTATION and MONITORING of UNDERWATER ARCHAEOLOGICAL SITES USING 3D IMAGING TECHNIQUES: The CASE STUDY of the "nYMPHAEUM of PUNTA EPITAFFIO" (BAIAE, NAPLES)

    Bruno F., Lagudi A., Collina M., Medaglia S., Davidde Petriaggi B., Petriaggi R., Ricci S., Sacco Perasso C.,

    ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 42(2/W10), pp. 53-59

    3D scanningImage Processing & Applications

    Abstract

    The preservation status of an underwater cultural site can be determined as the combination of two primary factors, namely the site physical integrity, which results from the past and present interaction of the site itself with the biological/chemical agents located in the surrounding environment, and the exposure of the site to human-related threats. Methods to survey underwater archaeological sites have evolved considerably in the last years in order to face the challenges and problems in archaeological prospection, documentation, monitoring, and data collection.This paper presents a case-study of an archaeological documentation campaign addressed to study and monitor the preservation status of an underwater archaeological site by combining the quantitative measurements coming from optical and acoustic surveys with the study of biological colonization and bioerosion phenomena affecting ancient artefacts. In particular, we present the first results obtained in the survey and documentation campaign carried out during the spring - summer 2018 in the "Nymphaeum of Punta Epitaffio" located in the Marine Protected Area - Underwater Park of Baiae (Naples).

    Keywords: 3D Imaging , 3D Mapping , Baiae Archaeological Park , Photogrammetry , Underwater Archaeology

  5. Editorial2018

    Advances on mechanics, design engineering and manufacturing

    Sequenzia G., Rizzuti S., Martorelli M., Ingrassia T.,

    International Journal on Interactive Design and Manufacturing, 12(4), pp. 1155-1156

    3D scanning3D technologies for cultural heritagesAdditive manufacturingDesign for sustainabilityEngineering educationGeometric dimensioning, tolerancing and inspectionHuman factors and ergonomicsImage Processing & ApplicationsMethods for medical applicationsProduct design and engineeringVirtual and augmented realityVirtual prototyping and digital twin

  6. Articolo su rivista2018

    Mechanical characterization and modeling of downwind sailcloth in fluid-structure interaction analysis

    Calì M., Oliveri S.M., Cella U., Martorelli M., Gloria A., Speranza D.,

    Ocean Engineering, 165, pp. 488-504

    3D scanning

    Abstract

    Computational Fluid Dynamics (CFD), as early used in the design stage, helps engineers to come up with the optimum design of a sail in a reasonable timeframe. However, traditional CFD tools are approximate and need to be validated when it comes to predicting the dynamic behaviour of non-developable shape with high camber and massively detached flow around thin and flexible membranes. Some of these approximations are related to the implementation of the constitutive material characteristics and assumption of their isotropic properties, while the sail aerodynamic performance is strongly influenced by the arrangement of sail panels as well as the orientation of the fibres in the composite structure. The present paper offers a methodology that enhances the understanding of the influence of panel arrangement and fibre orientation on sail performance. Fluid-structure-interaction (FSI) in a symmetric spinnaker was studied through an integrated CFD-CSM (Computational Structural Mechanics) analysis. A suitable triangular membrane element formulation of sail was adopted and the constitutive characteristics (elasticity and damping) of the Nylon superkote 75 were implemented in CSM model after being experimentally measured. The aerodynamic performance of sail in terms of drive force and side force was evaluated using both Reynolds Averaged Navier Stokes Simulations (RANS) and Shear Stress Transport (SST) turbulence model with a finite volume approach. A comparison between different panel arrangements was carried out under altered downwind flow conditions of wind speed and wind angle. Digital photogrammetry was employed to create the 3D reconstruction of the sail's flying shape and validate the results obtained by aeroelastic analysis.

    Keywords: CFD-CSM analysis , Flying shape photogrammetry acquisition , Sail panel arrangement , SST model , Triangular membrane elements

  7. Articolo su rivista2018

    Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs

    Zanetti E.M., Ciaramella S., Calì M., Pascoletti G., Martorelli M., Asero R., Watts D.C.,

    Dental Materials, 34(8), pp. 1235-1245

    Methods for medical applicationsProduct design and engineering

    Abstract

    Objective: To investigate the influence of implant design on the change in the natural frequency of bone-implant system during osseointegration by means of a modal 3D finite element analysis. Methods: Six implants were considered. Solid models were obtained by means of reverse engineering techniques. The mandibular bone geometry was built-up from a CT scan dataset through image segmentation. Each implant was virtually implanted in the mandibular bone. Two different models have been considered, differing in the free length of the mandibular branch (‘long branch' and ‘short branch') in order to simulate the variability of boundary conditions when performing vibrometric analyses. Modal analyses were carried out for each model, and the first three resonance frequencies were assessed with the respective vibration modes. Results: With reference to the ‘long branch' model, the first three modes of vibration are whole bone vibration with minimum displacement of the implant relative to bone, with the exception of the initial condition (1% bone maturation) where the implant is not osseointegrated. By contrast, implant displacements become relevant in the ‘short branch' model, unless osseointegration level is beyond 20%. The difference between resonance frequency at whole bone maturation and resonance frequency at 1% bone maturation remained lower than 6.5% for all modes, with the exception of the third mode of vibration in the ‘D' implant where this difference reached 9.7%. With reference to the ‘short branch' considering the first mode of vibration, 61–68% of the frequency increase was achieved at 10% osseointegration; 72–79% was achieved at 20%; 89–93% was achieved at 50% osseointegration. The pattern of the natural frequency versus the osseointegration level is similar among different modes of vibration. Significance: Resonance frequencies and their trends towards osseointegration level may differ between implant designs, and in different boundary conditions that are related to implant position inside the mandible; tapered implants are the most sensitive to bone maturation levels, small implants have very little sensitivity. Resonance frequencies are less sensitive to bone maturation level beyond 50%.

    Keywords: Bone properties , CAD , Dental materials , Endosteal implants , Finite element analysis , Implant stability , Material properties , Osseointegration , Reverse engineering

  8. Articolo su rivista2018

    FE analysis of conceptual hybrid composite endodontic post designs in anterior teeth

    Gloria A., Maietta S., Martorelli M., Lanzotti A., Watts D.C., Ausiello P.,

    Dental Materials, 34(7), pp. 1063-1071

    Image Processing & ApplicationsMethods for medical applicationsProduct design and engineering

    Abstract

    Objectives: To assess conceptual designs of dental posts consisting of polyetherimide (PEI) reinforced with carbon (C) and glass (G) glass fibers in endodontically treated anterior teeth. Methods: 3D tessellated CAD and geometric models of endodontically treated anterior teeth were generated from Micro-CT scan images. Model C-G/PEI composite posts with different Young's moduli were analyzed by Finite Element (FE) methods post A (57.7 GPa), post B (31.6 GPa), post C (from 57.7 to 9.0 GPa in the coronal–apical direction). A load of 50 N was applied at 45° to the longitudinal axis of the tooth, acting on the palatal surface of the crown. The maximum principal stress distribution was determined along the post and at the interface between the post and the surrounding structure. Results: Post C, with Young's modulus decreasing from 57.7 to 9.0 GPa in the coronal–apical direction, reduced the maximum principal stress distribution in the restored tooth. Post C gave reduced stress and the most uniform stress distribution with no stress concentration, compared to the other C-G/PEI composite posts. Significance: The FE analysis confirmed the ability of the functionally graded post to dissipate stress from the coronal to the apical end. Hence actual (physical) C-G/PEI posts could permit optimization of stress distributions in endodontically treated anterior teeth.

    Keywords: CAD , Dental materials , Design , Endodontic treatment , Finite Element analysis , Image analysis

  9. Articolo su rivista2018

    Influence of thread shape and inclination on the biomechanical behaviour of plateau implant systems

    Calì M., Zanetti E.M., Oliveri S.M., Asero R., Ciaramella S., Martorelli M., Bignardi C.,

    Dental Materials, 34(3), pp. 460-469

    Methods for medical applicationsProduct design and engineering

    Abstract

    Objective: To assess the influence of implant thread shape and inclination on the mechanical behaviour of bone-implant systems. The study assesses which factors influence the initial and full osseointegration stages. Methods: Point clouds of the original implant were created using a non-contact reverse engineering technique. A 3D tessellated surface was created using Geomagic Studio® software. From cross-section curves, generated by intersecting the tessellated model and cutting-planes, a 3D parametric CAD model was created using SolidWorks® 2017. By the permutation of three thread shapes (rectangular, 30° trapezoidal, 45° trapezoidal) and three thread inclinations (0°, 3° or 6°), nine geometric configurations were obtained. Two different osseointegration stages were analysed: the initial osseointegration and a full osseointegration. In total, 18 different FE models were analysed and two load conditions were applied to each model. The mechanical behaviour of the models was analysed by Finite Element (FE) Analysis using ANSYS® v. 17.0. Static linear analyses were also carried out. Results: ANOVA was used to assess the influence of each factor. Models with a rectangular thread and 6° inclination provided the best results and reduced displacement in the initial osseointegration stages up to 4.58%. This configuration also reduced equivalent VM stress peaks up to 54%. The same effect was confirmed for the full osseointegration stage, where 6° inclination reduced stress peaks by up to 62%. Significance: The FE analysis confirmed the beneficial effect of thread inclination, reducing the displacement in immediate post-operative conditions and equivalent VM stress peaks. Thread shape does not significantly influence the mechanical behaviour of bone-implant systems but contributes to reducing stress peaks in the trabecular bone in both the initial and full osseointegration stages.

    Keywords: Bone properties , CAD , Dental materials , Endosteal implants , Finite element analysis , Material properties , Osseointegration , Plateau implants

  10. Articolo su rivista2018

    A comparison among additive manufactured polymeric complete dental models resulting from intraoral scans: An in vivo study

    Russo L.L., Zhurakivska K., Speranza D., Salamini A., Ciavarella D., Ciaramella S., Martorelli M.,

    International Review on Modelling and Simulations, 11(1), pp. 1-4

    3D scanningAdditive manufacturingMethods for medical applications

    Abstract

    The use of intraoral scanners and Additive Manufacturing (AM) techniques in dentistry is increasing, and such technologies are integrated in daily workflows for the production of various types of dental restorations. Thus, it is clinically sensible to assess the accuracy of these systems. This in vivo study presents a comparison, in term of accuracy, among three commercially available AM systems, used to rapid prototype models obtained from intraoral scans data. Eight patients with a complete dentition were selected. Complete-arch scans of both upper and lower jaws were obtained using the 3Shape Trios 3 color intraoral scanner. The corresponding CAD models were created by means of the 3Shape Dental System software, and three AM systems, Photocentric LC10 (AM1), Zortrax M 200 (AM2) and Prusa I3 (AM3) were used to manufacture them. The manufactured fourty-eight models were scanned with the 3Shape Trios 3 color scanner, by the same operator. Scans of the manufactured models were aligned and compared to the reference intraoral scan by means of a Reverse Engineering software (Geomagic Studio). The comparison between the scans of the manufactured models and the reference intraoral scans, for the eight patients, shows a standard deviation (SD) in the range 0.11 – 0.27 mm for AM1, in the range 0.04 – 0.26 mm for AM2 and in the range 0.07 – 0.26 mm for AM3. The results of this research show that Prusa I3 and Zortrax M 200 are statistically more accurate than Photocentric LC10. Nevertheless, if we consider the amount of difference in accuracy, this may be not relevant from a clinical point of view. Thus, the three AM systems can be used in some dental applications which are compatible with the reported accuracy.

    Keywords: Additive manufacturing , Dental models , Dentistry , Intraoral scans , Orthodontic appliances

  11. Articolo su rivista2018

    Experimental study on hydrodynamic performances of naval propellers to adopt new additive manufacturing processes

    Staiano G., Gloria A., Ausanio G., Lanzotti A., Pensa C., Martorelli M.,

    International Journal on Interactive Design and Manufacturing, 12(1), pp. 1-14

    3D scanningAdditive manufacturingDesign methods for mobility

    Abstract

    In the past few years, a new generation of additive manufacturing (AM) techniques has rapidly become available due to the expiration of some AM patents which allowed significant cost reductions. This article explores some available techniques fostering products innovation in experimental laboratories for the development of naval propulsion, where high costs represent an important limitation for both basic research and industrial testing, by identifying significant knowledge and variables and by providing reliable and accurate data to support designers and researchers. The propeller INSEAN E779a case study was taken into account and fabricated by direct metal laser sintering in AlSi10Mg aluminium alloy and by fused deposition modeling in acrylonitrile–butadiene–styrene, and UltraT polymeric materials. The study of printing parameters, flexural tests, differential scanning calorimetry and thermogravimetric analysis, allowed to optimize the printing process conditions. A reverse engineering system, Faro-CAM2, and the iterative closest point algorithm of the geomagic control software were used to analyse deviations from the printed propeller and the CAD nominal model. The atomic force microscopy test allowed to assess the morphological features and surface roughness of printed propellers. Towing Tank tests were carried out and the hydrodynamic performance comparison was analysed in terms of torque and drag. The results of this study show differences between the benchmark and AM propellers, as a function of the advance coefficient J, the morphological characteristics and the materials. However this study also shows a substantial adequacy of AM propellers in most studies carried out in Towing Tank.

    Keywords: Additive manufacturing (AM) , Marine propeller , Reverse engineering (RE)

  12. Articolo su rivista2018

    Secondary features segmentation from high-density tessellated surfaces

    Di Angelo L., Di Stefano P., Morabito A.E.,

    International Journal on Interactive Design and Manufacturing, 12(3), pp. 801-809

    Abstract

    A new method for secondary features segmentation, performed on high-density tessellated geometric models, is proposed. Four types of secondary features are considered: fillets, rounds and grooves. Sharp edges are also recognised. The method is based on an algorithm that analyses the principal curvatures. The nodes, potentially attributable to a fillet of given geometry, are those with a certain value for the maximum principal curvature. Since the deterministic application of this simple working principle shows several problems, due to the uncertainties in the curvature estimation, a fuzzy approach is proposed. In order to segment the nodes of a tessellated model belonging to secondary features of a given radius, an appropriate set of membership functions is defined and evaluated based on some parameters, which affect the quality of the curvature estimation. A region-growing algorithm connects the nodes pertaining to a same secondary feature so that, for a given radius, one or more secondary features may be recognized. The method is applied and verified in some test cases.

    Keywords: Computational geometry , Features extractions , Fuzzy logic , Mechanical engineering computing , Region growing algorithm

  13. Articolo su rivista2018

    Axis estimation of thin-walled axially symmetric solids

    Angelo L.D., Stefano P.D.,

    Pattern Recognition Letters, 106, pp. 47-52

    3D technologies for cultural heritages

    Abstract

    In this paper, a new method for axis detection of discrete thin-walled axially symmetric surfaces is presented. This method is based on the property of thin-walled axially symmetric surfaces that the minimum path of a point on the external wall to the internal wall is on a straight line passing through the axis. This working principle, since it does not require the evaluation of differential geometrical properties, makes the method robust to noise. The proposed method has been applied in a very critical application area: axially symmetric archaeological pottery fragments, for which the evaluation of the axis is complex because of manufacturing error and of modification of the surface properties due to the action of time and weather. The trueness of the proposed method is compared with those of the five methods presented in the literature in the analysis of real sherds of various dimensions and conditions. The proposed method demonstrates greater robustness than these methods and is shown to be promising to improve the number of sherds that can be successfully analyzed.

    Keywords: 3D archeology , Axis estimation , Computer , Geometric inspection , Methods in archaeology

  14. Articolo su rivista2018

    Biomechanical analysis of the humeral tray positioning in reverse shoulder arthroplasty design

    Ingrassia T., Nalbone L., Nigrelli V., Ricotta V., Pisciotta D.,

    International Journal on Interactive Design and Manufacturing, 12(2), pp. 651-661

    3D scanningProduct design and engineeringVirtual prototyping and digital twin

    Abstract

    Despite the widespread use of reverse total shoulder arthroplasty, the fundamental effects of implant configuration on certain biomechanical outcomes have not been completely elucidated especially for the most innovative prostheses. Aim of this work is to investigate the behaviour of a new reverse shoulder prosthesis, characterized by a humeral tray with a variable offset, designed to increase the range of motion and to reduce the impingement. The purposes of this study were to evaluate the effect of reverse shoulder implant design parameters on the deltoid muscle forces, required to produce abduction, and on the shoulder range of motion, in order to provide a more systematic understanding of the fundamental effects of humeral component positioning on the implant performances. The study has been implemented using virtual prototypes of the shoulder-prosthesis assembly. The shape of the prosthesis has been digitally acquired via a 3D scanner and the CAD models of all the components have been created. Through CT images, 3-dimensional models of the shoulder bones have been reconstructed and assembled with the prosthesis components. Numerical FEM models have been set up in order to evaluate how the abduction force changes depending on the humeral tray offset. Using the virtual prototypes of the shoulder-prosthesis assembly, a range of motion analysis has been carried out by setting up a collision detection analysis in a 3D parametric modeling environment. Different humeral tray positions were investigated and four different motions of the arm were simulated. Obtained results have demonstrated that a suitable positioning of the humeral tray can offer significant biomechanical advantages in terms of range of motion and abduction force.

    Keywords: CAD , FEM , Reverse engineering , Reverse shoulder prosthesis , Virtual prototyping

  15. Articolo su rivista2018

    New algorithms to evaluate the real shape of a hull

    Di Paola F., Ingrassia T., Brutto M.L., Mancuso A., Nigrelli V.,

    Journal of Engineering and Applied Sciences, 13(7), pp. 1638-1643

    3D scanningDesign methods for mobilityVirtual prototyping and digital twin

    Abstract

    In this study, a new method to compare rebuilt surfaces of hulls of sailing yachts is presented. In particular, the considered rebuilt surfaces are created through classic reverse engineering approaches. The new method has been developed by means of Grasshopper, a free generative algorithms editor that can be used as plugin of Rhinoceros, one of the most widespread free-form modelling software. In particular, two different algorithms have been developed: the first one allows controlling the quality of the rebuilt surfaces, the second one, instead, allows to measure the deviations between the original CAD Model and the rebuilt surface of the hull. A case study related to the hull of a small sailing yacht is also presented. The obtained results have demonstrated the efficiency of the new proposed low-cost method.

    Keywords: CAD Model , CAE tools , Close range photogrammetry , Generative algorithms , Low-cost reverse engineering analysis , Sailing yacht

  16. Articolo su rivista2018

    Extending VTK library to dynamically modify polygonal meshes in medical applications

    Vitali A., Regazzoni D., Rizzi C., Colombo G.,

    Computer-Aided Design and Applications, 15(2), pp. 203-210

    3D scanningMethods for medical applications

    Abstract

    Rising reverse engineering applications require the use of 3D models based on polygonal meshes and a set of modeling operations to shape the final product. Usually, 3D modeling tools do not exploit existing software development kits for developing custom virtual applications. This approach can be very useful for reverse engineering process in the medical field. The paper describes the software development of local mesh modeling algorithms as an extension of the open source library VTK with the aim of shaping 3D triangulated meshes. Then, a case study has been considered to create virtual modeling tools supporting the design process of custom-fit products and, in particular, of lower limb prosthetic socket for amputees. The application has been tested to design a socket for a patient with an above knee amputation. Results reached so far provide a positive feedback on the quality of the designed process and outcome, mainly thanks to the use of the virtual tools based on the developed software modules for 3D mesh modeling.

    Keywords: medical devices , Polygonal 3D modeling , prosthesis design , VTK

  17. Contributo a convegno2018

    Truss design and optimization using stress analysis and NURBS curves

    Caputi A., Cohen M.W., Rizzi C., Russo D.,

    ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE), 13

    Additive manufacturingProduct design and engineeringVirtual prototyping and digital twin

    Abstract

    This paper presents a novel design methodology, which combines topology and shape optimization to define material distribution in the structural design of a truss. Firstly, in order to identify the best layout, the topology optimization process in the design domain is carried out by applying the BESO (Bidirectional Evolutionary Structural Optimization) method. In this approach, the low energy elements are eliminated from an initial mesh, and a new geometry is constructed. This new geometry consists of a set of elements with a higher elastic energy. This results in a new division of material providing different zones, some subjected to higher stress and others containing less elastic energy. Moreover, the elements of the final mesh are re-arranged and modified, considering the distribution of tension. This new arrangement is constructed by aligning and rotating the original mesh elements coherently to the principal directions. In the Shape Optimization stage, the resulting TO (Topology Optimization) geometry is refined. A process of replacing the tabular mesh is performed by rearranging the remaining elements. The vertices of the mesh are set as control polygon vertices and used as reference to define the NURBS (Non-Uniform Rational B-Spline) curves. This provides a parametric representation of the boundaries, outlining the high elastic energy zones. The final stage is the optimization of the continuous and analytically defined NURBS curve outlining the solid material domain. The Shape Optimization is carried out applying a gradient-based optimization method.

  18. Articolo su rivista2018

    A cyber-physical system for production monitoring of manual manufacturing processes

    Tarallo A., Mozzillo R., Di Gironimo G., De Amicis R.,

    International Journal on Interactive Design and Manufacturing, 12(4), pp. 1235-1241

    Human factors and ergonomics

    Abstract

    The computerization of manufacturing is one of the major challenges of the so-called fourth industrial revolution or Industry 4.0. Virtualization of the smart factory should provide real-time vision, control and monitoring of production through interactive dashboards and synchronization of data coming from different factory functions. The latter characteristics are particularly difficult to implement when the manufacturing core relies on traditional manual labour rather than on automation, as in the case of manual assembly. Monitoring or even controlling the manual work in real-time is extremely difficult to put into practice. Therefore, realizing the principles of Industry 4.0 in manual or semi-automatic labour contexts means developing new production control systems that involve the worker in the monitoring process without negatively affecting the production times or the psychological status of the workers. In particular, the authors propose a computer-aided production control framework based upon multimedia manuals and smart completeness control systems that can be used to implement the principles of Industry 4.0 in manual or semi-automatic work environments. This technology has been successfully tested in laboratory on the basis of a real industrial case study. The response of the testers has been positive and the outcomes in terms of increased product quality are promising.

    Keywords: Cyber-physical systems , Industry 4.0 , Interactive electronic technical manuals , Production monitoring , Smart manufacturing

  19. Contributo a convegno2018

    Analytic solutions for the static equilibrium configurations of externally loaded cantilever soft robotic arms

    Grazioso S., Di Gironimo G., Siciliano B.,

    2018 IEEE International Conference on Soft Robotics, RoboSoft 2018, pp. 140-145

    Abstract

    In this paper we derive the analytic solutions for the statics of cantilever soft arm under external loading. The main motivation behind this work is the development of manageable and ready-to-use mathematical models of soft robotic arm for various purposes. We formulate the problem exploiting the Lie group structure of the arms' configuration space. This allows using the powerful mathematical tools from differential geometry. The model builds upon the theory of Cosserat rods: The mechanics-based perspective used to describe the kinematics and statics allows including into the model the large deformations due to axial, shear, torsion and bending effects. The position fields of the manipulators' shapes are analytically integrated and validated with respect to exact solutions and experiments.

    Keywords: Cosserat rods , differential geometry , mathematical modeling , Soft robotics

  20. Articolo su rivista2018

    Design and development of a novel body scanning system for healthcare applications

    Grazioso S., Selvaggio M., Di Gironimo G.,

    International Journal on Interactive Design and Manufacturing, 12(2), pp. 611-620

    3D scanningImage Processing & Applications

    Abstract

    This paper presents a novel instant 3D whole body scanner for healthcare applications. It is based on photogrammetry, a digital technology which allows to reconstruct the surface of objects starting from multiple pictures. The motivation behind this work is the development of minimally invasive procedures for instant data acquisitions of anatomical structure. The scanner provides several features of interests in 3D body scanning technologies for the healthcare domains: (i) instant capture of human body models; (ii) magnitude of accuracy in the order of 1 mm; (iii) simplicity of use; (iv) possibility to scan using different settings; (v) possibility to reconstruct the texture. The system is built upon a modular and distributed architecture. In this paper we highlight its key concepts and the methodology which has led to the current product. We illustrate its potential through one of the most promising 3D scanning healthcare applications: the data acquisition and processing of human body models for the digital manufacturing process of prostheses and orthoses. We validate the overall system in terms of conformity with the the initial requirements.

    Keywords: 3D reconstruction , Body scanning , Healthcare , Human body measurements , Human body visualization , Photogrammetry , Proshetics and orthotics