Geometric dimensioning, tolerancing and inspection

Ambito disciplinare

  1. Contributo a convegno2020

    Low cost markerless motion capture systems: A comparison between rgb cameras and rgb-d sensors

    Vitali A., Regazzoni D., Rizzi C., Lupi G.,

    ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE), 6

    Abstract

    In the last years, the advent of low-cost markerless motion capture systems fostered their use in several research fields, such as healthcare and sport. Any system presents benefits and drawbacks that have to be considered to design a Mocap solution providing a proper motion acquisition for a specific context. In order to evaluate low-cost technology, this research work focuses on the evaluation of the accuracy of two categories of devices: The RGB active cameras and the RGB-D, or depth sensors devices. In particular, GoPro Hero 6 active cameras and Microsoft Kinect v2 devices have been selected as representative of the two categories. In particular, this work evaluates and compares the performances of the two systems used to track the position of human articulations. The two devices have been chosen among those available on the market after a state of the art has been completed. Before starting with the campaign of acquisition, the number of sensors and their layout have been designed to optimize the acquisition with both mark-less Mocap systems. Their comparison is based on a list of specific movements of upper and lower limbs. Each movement has been acquired simultaneously, to guarantee the same test conditions. The results have been organized, compared and discussed by evaluating performances and limitations of both solutions related to specific context of use. Conclusions highlight the best candidate technology..

    Keywords: Accuracy , active cameras , GoPro , Markerless Mocap systems , Microsoft Kinect

  2. Contributo a convegno2020

    Comparison of Algorithms for Recognition of Cylindrical Features in a Voxel-Based Approach for Tolerance Inspection

    Bici M., Campana F.,

    Lecture Notes in Mechanical Engineering, pp. 213-225

    Geometric modeling and processing

    Abstract

    In injection molding production, automatic inspections are needed to control defects and evaluate the assigned functional tolerances of components and dies. With the “Smart Manufacturing” approach as a point of view, this paper resumes part of a wider research aiming the integration and the automation of a Reverse Engineering inspection process in components and die set-up. The paper compares two fitting approaches for recognition of portions of cylindrical surfaces. Therefore, they are evaluated in the respect of an automatic voxel-based feature recognition of 3D dense cloud of points for tolerance inspection of injection-molded parts. The first approach is a 2D Levenberg Marquardt algorithm coupled with a first guess evaluation made by the Kasa algebraic form. The second one is a 3D fitting based on the RANdom SAmple Consensus algorithm (RANSAC). The evaluation has been made according to the ability of the approaches of working on points associated to the voxel structure that locally divides the cloud to characterize planar and curved surfaces. After the presentation of the overall automatic recognition, the cylindrical surface algorithms are presented and compared trough test cases.

    Keywords: Injection molding , RANdom SAmple Consensus algorithm , Tolerance inspection

  3. Contributo a convegno2020

    Knee prostheses reverse engineering: A preliminary investigation

    Rossoni M., Regazzoni D., Vitali A., Colombo G., Spandre L., de Caro F.,

    Proceedings of the ASME Design Engineering Technical Conference, 9

    3D scanningGeometric modeling and processingMethods for medical applications

    Abstract

    Total Knee Arthroplasty is one of the most commonly performed orthopedic procedures and it is expected to grow in the next future . In the last past years, computer-assisted procedures represent one of the trends that are transforming the way of practicing medicine. Cornering the Total Knee Arthroplasty, digital models of the joints have been used to carry out simulation of their kinematics and mechanical performance. Whilst for the 3D digital reconstruction of the patient geometry several studies have been conducted, an approximated geometry of the prosthesis has been several times employed, with undeniable consequences on the final results. This paper aims at comparing two non-contact reverse engineering technologies to acquire the shape of femoral components employed for total knee arthroplasty. A high-level device (Konika Minolta Vivid 9i) and a mid-low cost laser (NextEngine) has been compared. For the comparison, a systematic procedure of acquisition and elaboration of the results has been adopted in order to have as unbiased as possible results. The procedure involves the use of the proprietary software of the scanners for the elaboration of the raw data and the meshing procedure has been kept the same for all the models. Since the as-is acquired mesh is of high-resolution, a decimation procedure has been carried out in order to make the 3D models lighter and easier to be handled. Once the decimation procedure has been evaluated comparing the original and the simplified models to one another, the digitalized models have been compared with the measurements taken from a coordinate measuring machines. As a preliminary result, the two lasers seem to be adequate to accomplish the reverse engineering process as required by this application. Of course, the mid-low cost laser would be preferable whether the performance will be confirmed to be (statistically) equal.

  4. Articolo su rivista2020

    Numerical and experimental validation of SMArt thermography for the inspection of wind blade composite laminate

    De Giorgi M., Nobile R., Saponaro A.,

    SN Applied Sciences, 2(10)

    Abstract

    An innovative active thermography technique is proposed for the inspection of typical wind blade material. The proposed technique is based on the use of a multifunctional material obtained adding a grid of Shape Memory Alloy wires, which would serve also as a protection against lightning, to a traditional glass fibre composite panel. This technique, called SMArt thermography, which exploits the SMA wires as internal heat sources, has been compared to a traditional pulsed thermography in the case of a representative panel of unidirectional glass fibre and epoxy matrix with embedded SMA wires and artificial defects. The experimental results of the two techniques are reported and compared to the result of a numerical FEM transient model, in order to establish the reliability and the detectability limit of the proposed technique. The FEM model has been proven to be a useful tool for the definition of the multifunctional material at a design stage.

    Keywords: Defect detection , Multifunctional materials , Shape memory alloy , SMArt thermography , Wind blades

  5. Articolo su rivista2020

    Influence of ceramic firing on marginal gap accuracy and metal-ceramic bond strength of 3D-printed Co-Cr frameworks

    Di Fiore A., Savio G., Stellini E., Vigolo P., Monaco C., Meneghello R.,

    Journal of Prosthetic Dentistry, 124(1), pp. 75-80

    Additive manufacturingMethods for medical applications

    Abstract

    Statement of problem: The marginal gap and ceramic bond strength of metal-ceramic restorations are important for success. However, studies evaluating the marginal gap and ceramic bond strength of fixed partial dentures (FPDs) produced with 3D printing technologies such as selective laser melting (SLM) are scarce. Purpose: The purpose of this in vitro study was to investigate the marginal gap of cobalt-chromium (Co-Cr) alloy frameworks produced by SLM technology before and after ceramic firing. Additionally, the metal-ceramic bond strength was evaluated with the Schwickerath crack-initiation test according to the International Standards Organization (ISO) 9693-1:2012. Material and methods: Conventional impressions were made, and the definitive cast of a patient requiring a 4-unit FPD was scanned. After designing the FPD, the files were sent to a service center for the fabrication of a metal master model, 80 Co-Cr frameworks, and 80 flat specimens (25×3×0.5 mm) with SLM technology. The marginal gap between frameworks and the abutment tooth of the metal master model was nondestructively measured by using an optical coordinate-measuring machine. A total of 80 sets, consisting of 1 framework and 1 flat specimen, were sent to 80 dental laboratory technicians for ceramic firing. Detailed instructions for correct manipulation of the framework and flat specimen were provided. The marginal gap was remeasured, and the 3-point bend test was used to evaluate metal-ceramic bond strength. Results: Only 28 of the 80 dental technicians returned the specimens within a prespecified time and/or in adequate condition. The mean ±standard deviation marginal gap of the framework before ceramic firing was 25 ±9 μm and 34 ±12 μm after firing. The difference was statistically significant (P=.001). The mean ±standard deviation 3-point bend strength was 33 ±9 MPa. Conclusions: Ceramic firing affected the marginal gap; however, all Co-Cr frameworks had a marginal gap lower than 120 μm, which is reported to be a clinically acceptable limit. Most of the specimens (80%) had a metal-ceramic bond strength value higher than the 25-MPa ISO 9693 requirement. Five of 28 dental laboratory technicians were not able to comply with ceramic firing instructions.

  6. Articolo su rivista2020

    Determinant assembly approach for flat-shaped airframe components

    Iaccarino P., Inserra S., Cerreta P., Mozzillo R.,

    International Journal of Advanced Manufacturing Technology, 108(7-8), pp. 2433-2443

    Abstract

    The optimization of the aeronautical structure manufacturing is a challenging task in the development of a new aircraft. To date, aeronautical industries are funding research about new assembly approaches based on cost reduction and increased efficiency of the assembly processes. The work here presented focused on an innovative assembly method based on the integration between statistical methods of tolerance prediction and the determinant assembly approach. The coupling tolerances between airframe components are predicted through statistical approach in order to reduce the features manufactured in assembly. This aspect contributes to a reduction of the costs due non-recurring costs. The method proposed has been tested on a dedicated case study developed in the frame of the “integrated main landing gear box” project on the CleanSky2 Research program. Tests have been conducted to check the consistency of the method and its feasibility in the industrial contexts in the case of flat-shaped component. The performed experiments confirmed the analytical study.

    Keywords: Aeronautical assembly process , Determinant Assembly , Determinate Assembly , Hole to hole , Statistical distribution , Tolerance prediction

  7. Contributo a convegno2019

    Integration of reverse engineering and ultrasonic non-contact testing procedures for quality assessment of CFRP aeronautical components

    Segreto T., Bottillo A., Caggiano A., Martorelli M.,

    Procedia CIRP, 79, pp. 343-348

    3D scanningDesign methods for mobility

    Abstract

    Nowadays, the quality assurance of aeronautical components is a very crucial issue. Diverse defects can be generated during composite material components manufacturing such as voids, delamination, cracks, etc. The identification of these defects requires the use of different types of inspection methods. In this paper, two diverse non-contact inspection techniques, i.e. a laser-based reverse engineering method and an ultrasonic testing procedure, are integrated to provide a complete quality assessment of carbon fibre reinforced polymer components for applications in the aeronautical field. A custom made software code was developed in order to create a user interface allowing for the visualization and analysis of the reverse engineering and ultrasonic information for the detection of geometrical and internal flaws of the component under inspection.

    Keywords: Composite materials , Laser-based reverse engineering , Non-contact testing , Quality control , Ultrasonic non-destructive inspection

  8. Contributo a convegno2019

    A compared approach on how deep learning may support reverse engineering for tolerance inspection

    Bici M., Mohammadi S.S., Campana F.,

    ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE), 14

    3D scanningGeometric modeling and processing

    Abstract

    Reverse Engineering (RE) may help tolerance inspection during production by digitalization of analyzed components and their comparison with design requirements. RE techniques are already applied for geometrical and tolerance shape control. Plastic injection molding is one of the fields where it may be applied, in particular for die set-up of multi-cavities, since no severe accuracy is required for the acquisition system. In this field, RE techniques integrated with Computer-Aided tools for tolerancing and inspection may contribute to the so-called “Smart Manufacturing”. Their integration with PLM and suppliers' incoming components may set the information necessary to evaluate each component and die. Intensive application of shape digitalization has to front several issues: accuracy of data acquisition hardware and software; automation of experimental and post-processing steps; update of industrial protocol and workers knowledge among others. Concerning post-processing automation, many advantages arise from computer vision, considering that it is based on the same concepts developed in a RE post-processing (detection, segmentation and classification). Recently, deep learning has been applied to classify point clouds, considering object and/or feature recognition. This can be made in two ways: with a 3D voxel grid, increasing regularity, before feeding data to a deep net architecture; or acting directly on point cloud. Literature data demonstrate high accuracy according to net training quality. In this paper, a preliminary study about CNN for 3D points segmentation is provided. Their characteristics have been compared to an automatic approach that has been already implemented by the authors in the past. VoxNet and PointNet architectures have been compared according to the specific task of feature recognition for tolerance inspection and some investigations on test cases are discussed to understand their performance.

    Keywords: Deep learning , Injection molding , PointNet , Reverse engineering , Tolerance inspection

  9. Articolo su rivista2019

    Robust die compensation in sheet metal design through the integration of dual response surface and shape function optimization

    Bici M., Campana F., Cimolin F., Rizzo L.,

    Mathematical Problems in Engineering, 2019

    Geometric modeling and processingProduct design and engineering

    Abstract

    In sheet metal forming, springback represents a major drawback increasing die set-up problems, especially for ultra-high strength steels. Finite Element Analysis is a well-established method to simulate the process during design, and multicriteria optimizations, for example, via surrogate models, are investigated in order to develop integrated design. Since to take into account also springback compensation die design may involve a large number of geometric variables, this paper presents a robust design formulation, based on the adoption of the shape function optimization, to describe springback in terms of weights directly associated to global shape variations of the die shape. Doing so, multicriteria optimization, which involves also die compensation, can be set up in a more intuitive approach, as requested in the preliminary steps of die design. After the introduction of the industrial problem, the mathematical formulation of the shape function optimization is presented together with its novel extension to Robust Design, which is based on the Dual Response Surface. Through a test case derived from the head part of a B-pillar, stamped from a Dual Phase sheet 1.5 mm thick, this novel extension investigates the effect of 6% variation from nominal values of initial yield stress and thickness. Results demonstrate the feasibility of the procedure, underlying that an optimal compensation may not be optimal in terms of process robustness.

  10. Articolo su rivista2019

    Accuracy of an automated three-dimensional technique for the computation of femoral angles in dogs

    Longo F., Savio G., Contiero B., Meneghello R., Concheri G., Franchini F., Isola M.,

    Veterinary Record, 185(14), pp. 443

    Abstract

    Aims: The purpose of the study was to evaluate the accuracy of a three-dimensional (3D) automated technique (computer-aided design (aCAD)) for the measurement of three canine femoral angles: anatomical lateral distal femoral angle (aLDFA), femoral neck angle (FNA) and femoral torsion angle. Methods:Twenty-eight femurs equally divided intotwo groups (normal and abnormal) were obtained from 14 dogs of different conformations (dolicomorphic and chondrodystrophicCT scans and 3D scanner acquisitions were used to create stereolithographic (STL) files, which were run in a CAD platform. Two blinded observers separately performed the measurements using the STL obtained from CT scans (CT aCAD) and 3D scanner (3D aCAD), which was considered the gold standard method. C orrelation coefficients were used to investigate the strength of the relationship between the two measurements. Results: A ccuracy of the aCAD computation was good, being always above the threshold of R 2 of greater than 80 per cent for all three angles assessed in both groups. a LDFA and FNA were the most accurate angles (accuracy >90 per cent). Conclusions: The proposed 3D aCAD protocol can be considered a reliable technique to assess femoral angle measurements in canine femur. The developed algorithm automatically calculates the femoral angles in 3D, thus considering the subjective intrinsic femur morphology. The main benefit relies on a fast user-independent computation, which avoids user-related measurement variability. The accuracy of 3D details may be helpful for patellar luxation and femoral bone deformity correction, as well as for the design of patient-specific, custom-made hip prosthesis implants.

    Keywords: 3D computation , accuracy , dogs , femur

  11. Book Chapter2019

    The influence of build orientation on the flatness error in artifact produced by direct metal laser sintering (DMLS) process

    Rizzuti S., De Napoli L., Ventra S.,

    Lecture Notes in Mechanical Engineering, pp. 463-472

    Additive manufacturing

    Abstract

    Additive Manufacturing (AM) involves a set of production processes in which a layer-based material deposition approach to build parts is applied. These technologies are now extensively used in the industry in many cases as the main manufacturing process for making components with high shape complexity. The dimensional and geometric accuracy of the parts manufactured by means of AM are mostly determined by the specific type of additive process employed and the related process parameters. The part orientation in the build space is an important process parameter that has an influence on the stair-step effect and on the need of support structures and the subsequent post-processing refinements. In addition, the position of the part in the build volume may have an influence on the shape. These factors concur to the surface finish and to the dimensional and shape accuracy. In this paper, the flatness error on several surfaces, built on a test artefact ad hoc conceived, has been measured by means of a CMM-based setup in order to quantify the variation of the error in relation to: The orientation of the surfaces with respect to the platform, and the position of the part in the build volume of the AM machine. The test part has been produced by Direct Metal Laser Sintering (DMLS) process using the EOS Stainless Steel GP1. The test artifact has been designed with five flat surfaces at different angles with respect to the building platform. Two specimens were built in the same DMLS session with different position and alignment. The influence of the surface slope on the flatness error has been investigated. Flatness, 3D Roughness and orientation errors (parallelism, inclination, perpendicularity) have been measured and compared between both specimens.

    Keywords: 3D surface roughness , Additive manufacturing , Flatness , Orientation error

  12. Book Chapter2019

    Accuracy assessment of CT-based 3D bone surface reconstruction

    Puggelli L., Uccheddu F., Volpe Y., Furferi R., Di Feo D.,

    Lecture Notes in Mechanical Engineering, pp. 487-496

    Methods for medical applications

    Abstract

    3D reconstruction of human anatomy from cross-sectional imaging has recently gained increasing importance in several medical fields thus designating the 3D bones reconstruction accuracy, critical for the success of the whole surgical intervention. The 3D anatomic model quality depends on the quality of the reconstructed image, on the quality of the images segmentation step and on the error introduced by the iso-surface triangulation algorithm. The influence of image processing procedures and relative parametrization has been largely studied in the scientific literature; however, the analysis of the direct impact of the quality of the reconstructed medical images is still lacking. In this paper, a comparative study on the influence of both image reconstruction algorithm (standard and iterative) and applied kernel is reported. Research was performed on the 3D reconstruction of a pig tibia, by using Philips Brilliance 64 CT scanner. At the stage of scanning and at the stage of 3D reconstruction, the same procedures were followed, while only image reconstruction algorithm and kernel were changed. The influence of such selection on the accuracy of bone geometry was assessed by comparing it against the 3D model obtained with a professional 3D scanner. Results show an average error in reconstructing the geometry of around 0.1 mm with a variance of 0.08 mm. The presented study highlights new opportunities to control the deviations on the geometry accuracy of the bones structures at the stage of cross sectional imaging generation.

    Keywords: 3D model reconstruction , Accuracy , Computed tomography , Kernel reconstruction

  13. Articolo su rivista2019

    Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners

    Di Fiore A., Meneghello R., Graiff L., Savio G., Vigolo P., Monaco C., Stellini E.,

    Journal of Prosthodontic Research, 63(4), pp. 396-403

    Abstract

    Purpose: Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). Methods: A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measured with a coordinate measuring machine. Eight different Ios were used to generate digital impression: True Definition, Trios, Cerec Omnicam, 3D progress, CS3500, CS3600, Planmeca Emelard and Dental Wings. Fifteen digital impressions were made. A software called “Scan-abut” was developed to analyse and compare the digital impression with the master model, obtaining the scanning accuracy. The three-dimensional (3D) position and distance analysis were performed. Results: Mean value of the 3D position analysis showed that the True Definition (31 μm ± 8 μm) and Trios (32 μm ± 5 μm) have the best performance of the group. The Cerec Omnicam (71 μm ± 55 μm), CS3600 (61 μm ± 14 μm) have an average performance. The CS3500 (107 μm ± 28 μm) and Planmeca Emelard (101 μm ± 38 μm) present a middle-low performance, while the 3D progress (344 μm ± 121 μm) and Dental Wings (148 μm ± 64 μm) show the low performance. The 3D distance analysis showed a good linear relationship between the errors and scan-abutment distance only with the True Definition and CS3600. Conclusions: Not all scanners are suitable for digital impression in full-arch implant-supported fixed dental prosthesis and the weight of the output files is independent from the accuracy of the Ios.

    Keywords: Accuracy , Dental implant , Digital impression , Full arch , Intraoral scanner

  14. Articolo su rivista2019

    Manufacturing of Metal Frameworks for Full-Arch Dental Restoration on Implants: A Comparison between Milling and a Novel Hybrid Technology

    Ciocca L., Meneghello R., Savio G., Scheda L., Monaco C., Gatto M.R., Micarelli C., Baldissara P.,

    Journal of Prosthodontics, 28(5), pp. 556-563

    Additive manufacturingGeometric modeling and processingMethods for medical applications

    Abstract

    Purpose: To determine the trueness and precision of frameworks manufactured with a selective laser melting/milling hybrid technique (SLM/m) and conventional milling by comparing the implant-platform/framework interface with those of the original computer-aided design (CAD). Materials and Methods: Using a virtual 6-implant-supported full-arch framework CAD drawing, 27 titanium replicas were manufactured by 3 independent manufacturing centers (n = 9/center) using a hybrid SLM/m technology (labs 1 and 2) or the conventional milling technique (lab 3). Using an opto-mechanical coordinate measuring machine, the frameworks' misfit distribution and patterns were analyzed, and the position error between paired platform positions within each framework was evaluated to calculate the misfit tendency for each group. A multilevel analysis using a mixed-effects model was conducted (α = 0.05). The trueness was evaluated as the dimensional difference from the original, while the precision as the dimensional difference from a repeated scan. Results: The 3 dimensional misfits differed significantly among the 3 groups, with the milled group exhibiting the least accurate outcome (p = 0.005). The mean 3D positioning errors ranged from 8 to 16 µm and from 9 to 22 µm for the SLM/m technique (labs 1 and 2, respectively), and from 20 to 35 µm for conventional milling (lab 3). Regarding the misfit distribution pattern, the misfit increased with the distance between paired platform positions in all groups. Conclusions: All groups had 3D misfits well within the error limits reported in the literature. The 3D misfits of new hybrid (SLM/milling) and conventional (milling) procedures differed significantly among them, with the milling technique the less accurate and precise. The largest errors in all groups were found between the most distant implants, resulting in a correlation between the framework span and the inaccuracies.

    Keywords: CAD/CAM , implant prosthesis , opto-mechanical measurement , oral rehabilitation , precision , trueness

  15. Contributo a convegno2019

    A Generalised Multi-Attribute Task Sequencing Approach for Robotics Optical Inspection Systems

    Vitolo F., Franciosa P., Ceglarek D., Patalano S., De Martino M.,

    2019 IEEE International Workshop on Metrology for Industry 4.0 and IoT, MetroInd 4.0 and IoT 2019 - Proceedings, pp. 117-122

    Design methods for mobility

    Abstract

    Robot programming usually consists of four steps: (1) task planning; (2) task sequencing; (3) path planning and (4) motion planning. Task (2) and (3-4) are strongly coupled. For example, the optimal robot path, which is function of the robot kinematics, relies on the pre-defined schedule of tasks, whose sequencing is computed based on the assumption that the travelling 'cost' from one task to the next is only driven by the Euclidean distance in Cartesian space. Current methods tends to decouple the problem and sequentially compute the task sequencing in the T-space, and then compute the robot path by solving the inverse kinematics in the C-space. However, those approaches suffer the capability to reach a global optimum. This paper aims at developing a novel approach which integrates some of the key computational requirements of the path planning in the early stage of the task sequencing. Multi-attribute objectives are introduced to take into account: robot pose and reachability, data quality, obstacles avoidance, overall cycle time. The paper introduces a novel multi-attribute approach to find the optimized task sequencing via candidate poses solving inverse kinematics in the T-space. This is based on the core idea to combine T-space and C-space. The proposed solution has been tested on a vision-based inspection robot system with application to automotive body assembly systems. Results could however impact a wider area, from navigation systems, game and graph theory, to autonomous driving systems.

    Keywords: Multi-attribute Optimization , Robot vision system , Robotic task sequencing , TSPN

  16. Articolo su rivista2019

    Measurement of high flexibility components in composite material: critical issues and possible solutions

    Polini W., Corrado A., Sorrentino L., Speranza D.,

    International Journal of Advanced Manufacturing Technology, 103(1-4), pp. 1529-1542

    3D scanningGeometric modeling and processing

    Abstract

    High-flexibility components in composite material are of great interest in many fields, from aeronautic and automotive industries to sport and design goods. Their deformation during cure process, known as spring-in and warpage, is acceptable if it is within the indicated tolerance. The research aim of the present work is to present a way to inspect a high flexible part in composite material by means of a coordinate measuring machine with a touch probe. This means to define the fixturing equipment and the measurement strategy. The developed method was applied to an L-shaped part with a very small thickness and the obtained measurements were compared with those due to a laser system. The results show a good agreement between the two measurement techniques. Moreover, the further numerical simulations validate the developed contact measurement method.

    Keywords: Composite material , Coordinate measuring machine , Flexible component , Laser

  17. Editorial2018

    Advances on mechanics, design engineering and manufacturing

    Sequenzia G., Rizzuti S., Martorelli M., Ingrassia T.,

    International Journal on Interactive Design and Manufacturing, 12(4), pp. 1155-1156

    3D scanning3D technologies for cultural heritagesAdditive manufacturingDesign for sustainabilityEngineering educationGeometric modeling and processingHuman factors and ergonomicsImage Processing & ApplicationsMethods for medical applicationsProduct design and engineeringVirtual and augmented realityVirtual prototyping and digital twin

  18. Contributo a convegno2018

    Tyres shoulder section characterization by means of ESPI

    Pagliarulo V., Memmolo P., Martorelli M., Timpone F., Ferraro P.,

    Proceedings of SPIE - The International Society for Optical Engineering, 10834

    Design methods for mobilityImage Processing & Applications

    Abstract

    In this work is exploited the possibility to use Electronic Speckle Pattern Interferometry (ESPI) for the characterization of different tyres with particular attention to the tyres shoulder section. Tyres characterization is of fundamental importance for vehicle dynamics modelling, since they are the main responsible of vehicles dynamical behaviour and thanks to their ability to deform, they allow to drive a vehicle generating the appropriate interaction forces at the interface with the road. Their behaviour is a consequence to their very complex structure. Two different racing tyres, one for car and other for motorcycle, have been considered. The investigation has been focused at the aim to evaluate and measure the section's components in order to get accurate information about the different layers along through the tyres shoulder section. Here we demonstrate that the different layers (rubber, nylon, steel) can be easily highlighted and identified by mean of the ESPI that, thanks to its high sensitivity, is capable to estimate the different out of plane displacement of the different layers that respond in a different way (i.e. with a different deformation) to a thermal stimulus highlighting the layers themselves. Moreover, we introduce a de-noising step in the reconstruction process: In particular we enhance the wrapped phase information by using a suitable algorithm called SPADEDH. It is important to note that the assessment about the different layers along the section is a very difficult task to obtain by visual inspection or classical microscopy. In fact, the condition of the cutted surface, or rather the strong inhomogeneity and the roughness make impossible to obtain good images especially in the shoulder area.

    Keywords: Holography , Non-destructive testing , Speckle , Tyre characterization

  19. Contributo a convegno2018

    A graph-based method and a software tool for interactive tolerance specification

    Patalano S., Vitolo F., Gerbino S., Lanzotti A.,

    Procedia CIRP, 75, pp. 173-178

    Product design and engineering

    Abstract

    The paper deals with the problem of tolerance specification and, in particular, proposes a graph-based method and a preliminary software tool: (i) to accomplish the tolerance specification for a mechanical assembly; (ii) to verify the consistency of the specification and, (iii) to allow the tracing of relationships among parts and features of the assembly. The method adopts Minimum Reference Geometric Elements (MRGE), directed graphs (di-graphs) and a set of dedicated algorithms to tackle the problems of consistency that occur during an interactive tolerance specification activity. Finally, an application illustrates the proposed method and its actual implementation.

    Keywords: Datum , GD&T , graph theory , MRGE , tolerance specification

  20. Articolo su rivista2018

    Advanced 3D photogrammetric surface reconstruction of extensive objects by UAV camera image acquisition

    Calì M., Ambu R.,

    Sensors (Switzerland), 18(9)

    Abstract

    This paper proposes a replicable methodology to enhance the accuracy of the photogrammetric reconstruction of large-scale objects based on the optimization of the procedures for Unmanned Aerial Vehicle (UAV) camera image acquisition. The relationships between the acquisition grid shapes, the acquisition grid geometric parameters (pitches, image rates, camera framing, flight heights), and the 3D photogrammetric surface reconstruction accuracy were studied. Ground Sampling Distance (GSD), the necessary number of photos to assure the desired overlapping, and the surface reconstruction accuracy were related to grid shapes, image rate, and camera framing at different flight heights. The established relationships allow to choose the best combination of grid shapes and acquisition grid geometric parameters to obtain the desired accuracy for the required GSD. This outcome was assessed by means of a case study related to the ancient arched brick Bridge of the Saracens in Adrano (Sicily, Italy). The reconstruction of the three-dimensional surfaces of this structure, obtained by the efficient Structure-From-Motion (SfM) algorithms of the commercial software Pix4Mapper, supported the study by validating it with experimental data. A comparison between the surface reconstruction with different acquisition grids at different flight heights and the measurements obtained with a 3D terrestrial laser and total station-theodolites allowed to evaluate the accuracy in terms of Euclidean distances.

    Keywords: Accuracy , Acquisition grid optimization , Digital surfaces models , Ground sampling distance , Structure-from-motion algorithms