3D scanning

Ambito disciplinare

  1. Editorial2021

    Editorial for underwater 3d recording & modelling

    Skarlatos D., Bruno F., Menna F., Nocerino E.,

    Remote Sensing, 13(4), pp. 1-3

  2. Articolo su rivista2020

    Novel concepts and strategies in skull base reconstruction after endoscopic endonasal surgery

    Solari D., Papallo I., Ugga L., Cavallo L.M., Onofrio I., Cuocolo R., Improta G., Brunetti A., Martorelli M., Gloria A., Cappabianca P., Russo T.,

    Acta IMEKO, 9(4), pp. 67-73

    Additive manufacturing

    Abstract

    Recently, a variety of craniofacial approaches has been adopted to enter the skull base, including the endonasal endoscopic technique. An effective watertight technique, the reconstruction can be performed using different materials, both autologous and non-autologous, individually or combined in a multilayer fashion. The current study focuses on the development of new advanced devices and techniques that help to reduce the postoperative cerebrospinal fluid leak rate. Additive manufacturing allows the design of devices with tailored structural and functional features, as well as injectable semi-interpenetrating polymer networks and composites; therefore, specific mechanical/rheological and injectability studies are valuable. Accordingly, we propose new additive manufactured and injectable devices.

    Keywords: Additive manufacturing , CSF leakage , Design of injectable systems , Endoscopic endonasal surgery , Reverse engineering , Skull base reconstruction

  3. Articolo su rivista2020

    Additive manufacturing and technical strategies for improving outcomes in breast reconstructive surgery

    Rocco N., Papallo I., Nava M.B., Catanuto G., Accurso A., Onofrio I., Oliviero O., Improta G., Speranza D., Domingos M., Russo T., de Santis R., Martorelli M., Gloria A.,

    Acta IMEKO, 9(4), pp. 74-79

    Additive manufacturing

    Abstract

    It has been widely reported that breast reconstruction improves the quality of life of women who undergo mastectomy for breast cancer. This approach provides many psychological advantages. Today, different techniques are available for the breast oncoplastic surgeon that involve the use of breast implants and autologous tissues, also offering interesting results in terms of aesthetic and patient-reported outcomes. On the other hand, advanced technologies and design strategies (i.e. design for additive manufacturing, reverse engineering) may allow the development of customised porous structures with tailored morphological, mechanical, biological, and mass transport properties. For this reason, the current study deals with the challenges, principles, and methods of developing 3D additive manufactured structures in breast reconstructive surgery. Specifically, the aim was to design 3D additive manufactured poly(ε-caprolactone) scaffolds with different architectures (i.e. lay-down patterns). Preliminary mechanical and biological analyses have shown the effect of the lay-down pattern on the performances of the manufactured structures.

    Keywords: Additive manufacturing , Breast reconstructive surgery , Fat grafting , Functional properties , Mechanical , Pore geometry and lay-down pattern , Reverse engineering , Scaffold design

  4. Contributo a convegno2020

    Optical characterizations of airless radial tire

    Martorelli M., Speranza D., Ferraro P., Genovese A., Gloria A., Pagliarulo V.,

    2020 IEEE International Workshop on Metrology for AeroSpace, MetroAeroSpace 2020 - Proceedings, pp. 561-565

    Geometric modeling and processing

    Abstract

    In this work is analyzed the possibility to use optical techniques for the characterization of airless radial tire. Electronic Speckle Pattern Interferometry (ESPI), laser scanner based on principle of triangulation and Digital Image Correlation (DIC) have been used to acquire and study this kind of tire. A MICHELIN® X® TWEEL® UTV has been considered as case study. The acquisitions have been used for the measurement of the shape for testing junction areas and to evaluate the structure behavior under a vertical load.

    Keywords: Composite laminates , Laser scanner , NDI , Tire

  5. Articolo su rivista2020

    Stress distributions for hybrid composite endodontic post designs with and without a ferrule: FEA study

    Ausiello P., Gloria A., Maietta S., Watts D.C., Martorelli M.,

    Polymers, 12(8)

    Geometric modeling and processingProduct design and engineering

    Abstract

    The aim of the current work was to analyze the influence of the ferrule effect for hybrid composite endodontic post designs consisting of carbon (C) and glass (G) fiber-reinforced polyetherimide (PEI), in upper canine teeth. Starting from theoretical designs of C-G/PEI hybrid composite posts with different Young's moduli (Post A-57.7 GPa, Post B-31.6 GPa, Post C-graduated from 57.7 to 9.0 GPa in the coronal-apical direction) in endodontically treated anterior teeth, the influence of the ferrule effect was determined through finite element analysis (FEA). On the surface of the crown, a load of 50 N was applied at 45° to the longitudinal axis of the tooth. Maximum principal stresses were evaluated along the C-G/PEI post as well as at the interface between the surrounding tooth structure and the post. Maximum stress values were lower than those obtained for the corresponding models without a ferrule. The presence of a ferrule led to a marked decrease of stress and gradients especially for posts A and B. A less marked effect was globally found for Post C, except in a cervical margin section along a specific direction, where a significant decrease of the stress was probably due to local geometric features, compared to the model without a ferrule. The presence of a ferrule did not generally provide a marked benefit in the case of the graduated Post C, in comparison to other C-G/PEI posts. The outcomes suggest how such a hybrid composite post alone should be sufficient to optimize the stress distribution, dissipating stress from the coronal to the apical end.

    Keywords: Computer-Aided Design , Endodontic post design , Finite element analysis , Polyetherimide composites , Reverse engineering

  6. Contributo a convegno2020

    Biomechanical Analysis of a New Elbow Prosthesis

    Ricotta V., Bragonzoni L., Marannano G., Nalbone L., Valenti A.,

    Lecture Notes in Mechanical Engineering, pp. 812-823

    Geometric modeling and processingProduct design and engineering

    Abstract

    Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model has been developed by modelling the forces of the muscles and after FEM analyses have been performed. Obtained results confirm the validity of the implemented model and can provide guidelines for surgeons regarding the implant configurations with the aim to reduce the aseptic loosening.

    Keywords: CAD , FEM , Reverse engineering , Total elbow arthroplasty

  7. Articolo su rivista2020

    Review of computer-based methods for archaeological ceramic sherds reconstruction

    Eslami D., Di Angelo L., Di Stefano P., Pane C.,

    Virtual Archaeology Review, 11(23), pp. 34-49

    3D technologies for cultural heritagesGeometric modeling and processing

    Abstract

    Potteries are the most numerous finds found in archaeological excavations; they are often used to get information about the history, economy, and art of a site. Archaeologists rarely find complete vases but, generally, damaged and in fragments, often mixed with other pottery groups. By using the traditional manual method, the analysis and reconstruction of sherds are performed by a skilled operator. Reviewed papers provided evidence that the traditional method is not reproducible, not repeatable, time-consuming and its results have great uncertainties. To overcome the aforementioned limits, in the last years, researchers have made efforts to develop computer-based methods for archaeological ceramic sherds analysis, aimed at their reconstruction. To contribute to this field of study, in this paper, a comprehensive analysis of the most important available publications until the end of 2019 is presented. This study, focused on pottery fragments only, is performed by collecting papers in English by the Scopus database using the following keywords: "computer methods in archaeology", "3D archaeology", "3D reconstruction", "automatic feature recognition and reconstruction", "restoration of pottery shape relics". The list is completed by additional references found through the reading of selected papers. The 53 selected papers are divided into three periods of time. According to a detailed review of the performed studies, the key elements of each analyzed method are listed based on data acquisition tools, features extracted, classification processes, and matching techniques. Finally, to overcome the actual gaps some recommendations for future researches are proposed.

    Keywords: 3D archaeology , 3D reconstruction , Automatic feature recognition and reconstruction , Computer methods in archaeology , Restoration of pottery shape relics

  8. Articolo su rivista2020

    A new design approach for customised medical devices realized by additive manufacturing

    Ricotta V., Campbell R.I., Ingrassia T., Nigrelli V.,

    International Journal on Interactive Design and Manufacturing, 14(4), pp. 1171-1178

    Additive manufacturingGeometric modeling and processing

    Abstract

    The aim of this work is the design of a new customised elbow orthosis completely realized by Additive Manufacturing and the development of generative algorithms for parametric modelling and creation of 3D patterns to be adapted to the CAD model. This work describes a method to perfect the design of a custom elbow orthosis. A reverse engineering approach has been used to digitalize the patient's arm and the subsequent CAD modelling of the structure of the custom elbow orthosis has been performed. In particular, two algorithms have been implemented for the creation of 3D patterns and Voronoi tessellations. Subsequently, FEM analyses have been carried out to validate the design. Finally, a prototype of the elbow orthosis with Voronoi tessellation has been realized by means of the SLS technology. The results obtained have demonstrated that the implemented algorithm solved the problems found during CAD modelling with conventional software. Furthermore, the results of FEM analyses have validated the design choices. All this allowed realizing the prototype by AM technologies without problems. Moreover, the new proposed modelling approaches allows creating, in an interactive way, patterns on complex surfaces. The results of this research activity present innovative elements of originality in the CAD modelling sector, which can contribute to solving problems related to the modelling for Additive Manufacturing. Furthermore, another innovative characteristic of the device is the use of torsion springs that simulate the action of physiotherapists during exercises for patient rehabilitation.

    Keywords: Additive manufacturing , Computer aided design , Elbow orthosis , Generative design , Reverse engineering

  9. Articolo su rivista2020

    Influence of the screw positioning on the stability of locking plate for proximal tibial fractures: A numerical approach

    Ingrassia T., Nigrelli V., Pecorella D., Bragonzoni L., Ricotta V.,

    Applied Sciences (Switzerland), 10(14)

    Geometric modeling and processingProduct design and engineering

    Abstract

    Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bone interface. A Schatzker type I tibial fracture was considered, and four different screw configurations were investigated. The obtained results demonstrated that, for this specific case study, screw orientation affected the pressure distribution at the screw/bone interface. The proposed approach could be used effectively to investigate different fracture types in order to give orthopaedists useful guidelines for the treatment of proximal tibial fractures.

    Keywords: CAD , FEM , Implant stability , Locking plates , Reverse engineering , Tibial fracture

  10. Contributo a convegno2020

    CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement

    Pasta S., Cannata S., Gentile G., Ingrassia T., Nigrelli V., Gandolfo C.,

    Lecture Notes in Mechanical Engineering, pp. 776-787

    Geometric modeling and processingProduct design and engineering

    Abstract

    The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty ring failure. Planimetric assessment of the cross-sectional area of the neo-LVOT was quantified at different anatomic levels of implanted THV. Findings revealed the importance of the proposed CAD modeling workflow to enable more informative pre-operative assessments of the risk related to the development of the neo-LVOT obstruction and even to guide the Heart Team regarding device selection, sizing and intended positioning for TMVR.

    Keywords: CAD , Medical imaging , Reverse engineering , Transcatheter mitral valve replacement , Virtual simulation

  11. Contributo a convegno2020

    3D Scanning Procedure for the Evaluation of Lymphedema of Upper Limbs Using Low-Cost Technolgy: A Preliminary Study

    Vitali A., Regazzoni D., Rizzi C., Molinero G.,

    Lecture Notes in Mechanical Engineering, pp. 177-188

    Abstract

    This research work presents a preliminary study for the assessment of lymphedema using low-cost 3D scanning and modelling technology. The aim is to develop a methodology to measure the anatomical key features of the upper limbs lymphedema using a 3D scanning technology and an ad-hoc developed application, named Lym 3DLab. The application is able to automatically measure both perimeters of cross sections and volumes of arm segments for medical evaluation and design of compression stockings using the upper limb polygonal mesh. The scanning procedure is based on a Microsoft Kinect v1 as scanner and the low-cost Skanect tool, which creates the polygonal mesh of the 3D acquisition. Lym 3DLab has been developed using open-source Software Development Kits, such as Qt and Visualization Toolkit. The acquired volumes have been compared with the water displacement method, which is considered the gold standard for measuring volumes of limbs affected by lymphedema. A preliminary test has been performed to compare volumes measured using the developed procedure with the gold standard. Five volunteers have been involved who are not affected by lymphedema. The arm volume measured with water displacement have been compared with the volume computed using 3D model of arm in Lym 3DLab. The range of differences is between −6,75 cm3 and 9,40 cm3. Reached results are the base for planning further test with a large number of patients affected by lymphedema in collaboration with a hospital.

    Keywords: 3D scanning , Automatic measurement of arm volume , Breast cancer , Lymphedema , Microsoft Kinect , Upper limb modeling

  12. Contributo a convegno2020

    High performance laser survey and 3D stress analysis for maintenance and preservation of artistic assets

    Marra A., Gerbino S., Fabbrocino G.,

    2020 IMEKO TC-4 International Conference on Metrology for Archaeology and Cultural Heritage, pp. 214-219

    Abstract

    The research described in this paper shows the results of preliminary analyses carried out on an artwork housed in a museum complex. A three-dimensional model of the sculpture, resulting from a laser scanner survey, has been analysed to understand its current state and seismic response, from a quantitative and qualitative point of view. The results highlight the great advantages resulting from integration of traditional and novel procedures in the field of conservation of artistic assets.

    Keywords: 3D analysis , Conservation , Documentation of cultural heritage , Laser scanning , Seismic risk

  13. Review2020

    Sensor architectures and technologies for upper limb 3d surface reconstruction: A review

    Paoli A., Neri P., Razionale A.V., Tamburrino F., Barone S.,

    Sensors (Switzerland), 20(22), pp. 1-33

    Methods for medical applications

    Abstract

    3D digital models of the upper limb anatomy represent the starting point for the design process of bespoke devices, such as orthoses and prostheses, which can be modeled on the actual patient's anatomy by using CAD (Computer Aided Design) tools. The ongoing research on optical scanning methodologies has allowed the development of technologies that allow the surface reconstruction of the upper limb anatomy through procedures characterized by minimum discomfort for the patient. However, the 3D optical scanning of upper limbs is a complex task that requires solving problematic aspects, such as the difficulty of keeping the hand in a stable position and the presence of artefacts due to involuntary movements. Scientific literature, indeed, investigated different approaches in this regard by either integrating commercial devices, to create customized sensor architectures, or by developing innovative 3D acquisition techniques. The present work is aimed at presenting an overview of the state of the art of optical technologies and sensor architectures for the surface acquisition of upper limb anatomies. The review analyzes the working principles at the basis of existing devices and proposes a categorization of the approaches based on handling, pre/post-processing effort, and potentialities in real-time scanning. An in-depth analysis of strengths and weaknesses of the approaches proposed by the research community is also provided to give valuable support in selecting the most appropriate solution for the specific application to be addressed.

    Keywords: Body scanner , Depth cameras , Handheld scanner , Stationary scanner , Structured light scanning , Upper limb 3D scanning

  14. Articolo su rivista2020

    3D acquisition and stereo-camera calibration by active devices: A unique structured light encoding framework

    Barone S., Neri P., Paoli A., Razionale A.V.,

    Optics and Lasers in Engineering, 127

    Abstract

    The use of light encoding techniques is widespread in the field of 3D surface reconstruction. This paper presents a stereo-camera calibration methodology, which integrates structured light encoding with an active digital device. The structured light encoding approach is proposed to unambiguously solve the stereo matching issue for stereo-camera setups. A sequence of vertical and horizontal binary striped patterns, combined with a checkerboard pattern, is displayed by a high-resolution LCD screen, which is used as calibration board. A bundle adjustment technique is adopted to simultaneously adjust both camera parameters and screen geometry, as part of the stereo-camera calibration process, thus taking into account the possible inaccuracies of the digital display. The same structured light approach, with small variants, is projected by a multimedia digital projector to carry out 3D surface reconstruction. The proposed methodology defines a comprehensive framework for the development of a 3D optical scanner, from calibration to 3D acquisition, which has been validated by measuring primitive surfaces and reconstructing free-form shapes with different stereo-camera setups.

    Keywords: Binary-code , LCD screen , Stereo-camera calibration , Stripe shifting , Structured light encoding

  15. Articolo su rivista2020

    Volumetric interpolation of tomographic sequences for accurate 3D reconstruction of anatomical parts

    Santarelli C., Argenti F., Uccheddu F., Alparone L., Carfagni M.,

    Computer Methods and Programs in Biomedicine, 194

    Geometric modeling and processing

    Abstract

    Background and objective:Tomographic sequences of biomedical images are commonly used to achieve a three-dimensional visualization of the human anatomy. In some cases, the number of images contained in the sequence is limited, e.g., in low-dose computed tomography acquired on neonatal patients, resulting in a coarse and inaccurate 3D reconstruction. Methods:In this paper, volumetric image interpolation methods, devised to increase the axial resolution of tomographic sequences and achieve a refined 3D reconstruction, are proposed and compared. The techniques taken into consideration are based on motion-compensated frame-interpolation concepts, which have been developed for video applications, mainly frame-rate conversion. Results: The performance of the proposed methods is quantitatively assessed by using sequences with a simulated low axial resolution obtained from the decimation of standard high-resolution computed tomography sequences. Real data with an actual low axial resolution have been used as well for a qualitative evaluation of the proposed methods. Conclusions:The experimental results demonstrate that the proposed methods enable an effective slice interpolation and that the achievable 3D models clearly benefit from the increased axial resolution.

    Keywords: 3D reconstruction , Biomedical image sequences , Computer tomography , Optical flow , Registration , Volumetric interpolation

  16. Contributo a convegno2020

    CAD Reconstruction: A Study on Reverse Modelling Strategies

    Buonamici F., Carfagni M., Furferi R., Governi L., Volpe Y.,

    Lecture Notes in Mechanical Engineering, pp. 165-176

    Geometric modeling and processingProduct design and engineering

    Abstract

    Computer Aided reconstruction of mechanical parts nowadays heavily relies on dedicated RE software systems and highly skilled users to be carried out effectively. This paper investigates this scenario in order to identify most limiting factors in the current framework. With this respect, several considerations of general validity are drawn while presenting the problem from a theoretical perspective. A significant test case reconstruction, discussed in depth in the manuscript, is used to provide a practical point of view on real applications and help the reader acquire a hands-on comprehension of the current situation.

    Keywords: CAD , CAD reconstruction , Reverse engineering

  17. Contributo a convegno2020

    A Preliminary 3D Depth Camera-Based System to Assist Home Physiotherapy Rehabilitation

    Uccheddu F., Governi L., Carfagni M.,

    Lecture Notes in Mechanical Engineering, pp. 696-706

    Geometric modeling and processingMethods for medical applications

    Abstract

    Total hip arthroplasty (THA) and total knee arthroplasty (TKA) have been recently heralded as the operations of the Century. Large improvements in mobility and patient-reported outcomes are typically observed compared with the small-to-moderate effects experienced with non-surgical interventions. Following surgery, physiotherapy-led exercise-based rehabilitation is often prescribed to yield better gait-related outcomes. Nevertheless, outpatient rehabilitation is expensive and heavily burden the national health service. When specific machines are not needed during the physiotherapy, patients, if assisted, can perform a home program. The purpose of this paper is to qualitatively investigate the applicability of a self-managed, home-based system for the automated evaluation of a home physiotherapy rehabilitation after TKA and THA. The system leverages the cost effectiveness and the versatility of a RGB-Depth camera system together with a commercial skeleton tracking system to analyse specific exercises. A novel computation of lower limb movements and related angles is proposed to evaluate the quality of the daily exercises. The laboratory experimental campaign, envisaged the analysis of the rotation angles of hips and knees; a lower limb schematic model is considered to estimate both knee and hip angles during ab/adductor and flex/extension movements. A novel real time calculation of the hip bone plane is proposed to assess the joint angles during specific exercises performance. A qualitative data analysis of each exercise has been performed. Results on the system usability in a domestic environment are reported as well as a visual comparison of the analysed output.

    Keywords: 3D , Body tracking , RGB-D camera

  18. Articolo su rivista2020

    Damage indices and photogrammetry for decay assessment of stone-built cultural heritage: The case study of the san domenico church main entrance portal (South Calabria, Italy)

    Randazzo L., Collina M., Ricca M., Barbieri L., Bruno F., Arcudi A., La Russa M.F.,

    Sustainability (Switzerland), 12(12)

    Geometric modeling and processingImage Processing & Applications

    Abstract

    In recent decades, increasing attention is being paid to the multidisciplinary approach that allows the performance of both a preventive conservation and a more invasive restoration action. In this context, the present study aims to acquire information and data from field surveys undertaken in San Domenico Church, Southern Calabria, in order to provide a tool for the recording and the inventory of damage and decay phenomena, and assess their causes and scale. The subsequent calculation of damage indices also provided useful information in order to allow the prioritization of conservation and preservation responses.

    Keywords: Built heritage , Calabria , Computer graphics , Damage diagnosis , Decay , Italy , Photogrammetry

  19. Contributo a convegno2020

    Design and Simulation of the Hull of a Small-Sized Autonomous Surface Vehicle for Seabed Mapping

    Barbieri L., Cucinotta F., Gallo A., Bruno F., Muzzupappa M., Penna N., Gaudio R.,

    Lecture Notes in Mechanical Engineering, pp. 422-431

    Additive manufacturingProduct design and engineering

    Abstract

    Autonomous Surface Vehicles are versatile marine vehicles that allow to fulfill a variety of offshore activities. Their versatility has been appreciated by the marine and aquatic science community, in fact, in the last years, a large number of ASVs have been developed in research projects and introduced in the market. In this paper, the design and simulation of a small-sized ASV for seabed mapping of shallow waters are described. The vehicle is characterized by catamaran shape, low draft, jet-drive propellers that allow its deployment from the shore, and a payload of 20 kg. The design process has been carried out with the aim to realize a vehicle characterized by ease of transportability and deployment, available payload and performance in terms of speed and endurance. Three hull types have been modelled in a computer-aided design environment and then optimized through fluid dynamics analysis for a cruise speed of 1.5 kN. The results of these simulations have been used to choose the best hull shape in terms of resistance, in order to comply with the constraints of autonomy and available payload. Finally, a scaled model of the best hull shape has been then tested in a circulating water channel to validate simulation data.

    Keywords: Additive manufacturing , Autonomous Surface Vehicle , Modeling and simulation , Shape design

  20. Contributo a convegno2020

    A preliminary approach on point cloud reconstruction of bronze statues through oriented photogrammetry: The “Principe Ellenistico” case

    Bici M., Gherardini F., Campana F., Leali F.,

    IOP Conference Series: Materials Science and Engineering, 949(1)

    3D technologies for cultural heritages

    Abstract

    Close-Range Photogrammetry is a widespread and efficient technique in the 3D acquisition of artefacts, particularly in fields like Cultural Heritage. Despite this wide usage, also due to a convenient quality/cost ratio, it shows some limitations due to light conditions as well as the artefact surface finishing. In this paper, we would like to report the assessment of a photogrammetry approach to 3D capture metal reflective surfaces, such as bronze, which is a widely used material in ancient statues. To this aim, we propose a photogrammetry workflow based on systematic steps capable of overcome some of the main issues of reflective surfaces. To validate this approach, the developed 3D model is compared to a more accurate model of the same artefact, obtained with a 3D scanner. As a case study, we selected the Principe Ellenistico, an ancient bronze statue conserved in the Museo Nazionale Romano (Rome, Italy), of which a photogrammetric model is firstly developed and then compared to the scanned one.

    Keywords: 3D acquisition , Bronze statue , Close-Range Photogrammetry , Principe Ellenistico , Systematic approach